HSGQ-QSFP-DAC:
· Maximum aggregate data rate: 40 Gb/s (4 x 10Gb/s)
· Support for multi-gigabit data rates :1 Gb/s - 10 Gb/s (per channel)
· QSFP+ conforms to the Small Form Factor SFF-8436
· 4-Channel Full-Duplex Passive Copper Cable
Quantity: | |
---|---|
HSGQ’s 40G QSFP+ direct attach passive cable uses shielded high-speed differential cable, whichIt conforms to 40g Ethernet ieee802.3ba standard and sff-8436 qsfp+ standard, supports 40g transmission rate, and is also downward compatible with low rate applications. Qsfp+ passive cable is the preferred solution for 40g rate short distance application, which is widely used in data transmission between data center and cabinet or between adjacent cabinets. Its biggest characteristics are low cost, ultra-low power consumption (less than 0.1W) and high reliability.
Features
● Maximum aggregate data rate: 40 Gb/s (4 x 10Gb/s)
● Support for multi-gigabit data rates :1 Gb/s - 10 Gb/s (per channel)
● QSFP+ conforms to the Small Form Factor SFF-8436
● 4-Channel Full-Duplex Passive Copper Cable
● Copper link length up to 5m (passive limiting)
● High-Density QSFP 38-PIN Connector
● Compatible to IEEE 802.3ba and SFF-8436
● Compatible to QSFP+ MSA
● Power Supply :+3.3V
● Low power consumption: 0.02 W (typ.)
● I2C based two-wire serial interface for EEPROM
● Signature which can be customized
● Temperature Range: 0~ 70 °C
● Comply with RoHS 6.0
Applications
● 10G/40G Ethernet
● InfiniBand 4x SDR/DDR/QDR
● 2/4/8/10G Fibre Channel
● Fibre Channel over Ethernet
● SAS, Servers, Hubs, Switches, and Routers
Recommended Operating Conditions
QSFP+ Host Board Schematic for passive copper cables
Pin Descriptions
Note 1: GND is the symbol for signal and supply (power) common for the QSFP+ module. All are common within the QSFP+ module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal-common ground plane.
Note 2: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power supplies and shall be applied concurrent- ly. Requirements defined for the host side of the Host Edge Card Connector are listed in Table 6. Recommended host board power supply filtering is shown in Figure 4. Vcc Rx Vcc1 and Vcc Tx may be internally connected with- in the QSFP+ Module module in any combination. The connector pins are each rated for a maximum current of 500mA.
Mechanical Dimensions
Ordering information
Note: You can be customized diameter and distance.
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by company before they become applicable to any particular order or contract. In accordance with company policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of company or others. Further details are available from any company sales representative.
HSGQ’s 40G QSFP+ direct attach passive cable uses shielded high-speed differential cable, whichIt conforms to 40g Ethernet ieee802.3ba standard and sff-8436 qsfp+ standard, supports 40g transmission rate, and is also downward compatible with low rate applications. Qsfp+ passive cable is the preferred solution for 40g rate short distance application, which is widely used in data transmission between data center and cabinet or between adjacent cabinets. Its biggest characteristics are low cost, ultra-low power consumption (less than 0.1W) and high reliability.
Features
● Maximum aggregate data rate: 40 Gb/s (4 x 10Gb/s)
● Support for multi-gigabit data rates :1 Gb/s - 10 Gb/s (per channel)
● QSFP+ conforms to the Small Form Factor SFF-8436
● 4-Channel Full-Duplex Passive Copper Cable
● Copper link length up to 5m (passive limiting)
● High-Density QSFP 38-PIN Connector
● Compatible to IEEE 802.3ba and SFF-8436
● Compatible to QSFP+ MSA
● Power Supply :+3.3V
● Low power consumption: 0.02 W (typ.)
● I2C based two-wire serial interface for EEPROM
● Signature which can be customized
● Temperature Range: 0~ 70 °C
● Comply with RoHS 6.0
Applications
● 10G/40G Ethernet
● InfiniBand 4x SDR/DDR/QDR
● 2/4/8/10G Fibre Channel
● Fibre Channel over Ethernet
● SAS, Servers, Hubs, Switches, and Routers
Recommended Operating Conditions
QSFP+ Host Board Schematic for passive copper cables
Pin Descriptions
Note 1: GND is the symbol for signal and supply (power) common for the QSFP+ module. All are common within the QSFP+ module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal-common ground plane.
Note 2: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power supplies and shall be applied concurrent- ly. Requirements defined for the host side of the Host Edge Card Connector are listed in Table 6. Recommended host board power supply filtering is shown in Figure 4. Vcc Rx Vcc1 and Vcc Tx may be internally connected with- in the QSFP+ Module module in any combination. The connector pins are each rated for a maximum current of 500mA.
Mechanical Dimensions
Ordering information
Note: You can be customized diameter and distance.
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by company before they become applicable to any particular order or contract. In accordance with company policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of company or others. Further details are available from any company sales representative.